Temperature Indicator
Eurotherm 3216I/AL/VH/RRX/R/4XL/G/ENG/ENG/XX/XXXX/XXXXXX/XXXXXX////// Temperature Indicator
- Product Code
3216I/AL/VH/RRX/R/4XL/G/ENG/ENG/XX/XXXX/XXXXXX/XXXXXX//////
- Category
Indicator
- Sub Category
Temperature Indicator
- Brand
Eurotherm
Specification
General
Environmental performance
Temperature limits Operation: 0 to 55°C
Storage: -10 to 70°C
Humidity limits Operation: 5 to 90% RH non condensing
Storage: 5 to 90% RH non condensing
Panel sealing: IP65, Nema 4X
Shock: BS EN61010
Vibration: 2g peak, 10 to 150Hz
Altitude: <2000 metres
Atmospheres: Not suitable for use in explosive or corrosive atmosphere
Electromagnetic compatibility (EMC)
Emissions and immunity: BS EN61326
Electrical safety
(BS EN61010): Installation cat. II; Pollution degree 2
Physical
Dimensions 3216i: 48W x 48H x 90D mm 3204i: 96W x 96H x 90D mm
32h8i: 96W x 48H x 90D mm
Weight 3216i: 250g 3204i: 420g 32h8i: 350g
Panel Mounting Cut out dimensions 3216i: 1/16 DIN 45W x 45H mm
3204i: 1/4 DIN 92W x 92H mm
32h8i: 1/8 DIN, horizontal 92W x 45H mm
Operator interface
Type: LCD TN with backlight
Main PV display 3216i, 3204i: 4 digits, green
32h8i: 5 digits, green or red Lower display 3216i, 3204i: 5 character starburst, green
32h8i: 9 character starburst, green
Status beacons: Units, outputs, alarms
Power requirements
3216i: 100 to 230Vac, ±15%,
48 to 62 Hz, max 6W
24Vac, -15%, +10%.
24Vdc, -15% +20% ±5% ripple voltage max 6W
32h8i, 3204i: 100 to 230Vac, ±15%,
48 to 62 Hz, max 8W
24Vac, -15%, +10%.
24Vdc -15% +20% ±5% ripple voltage max 8W
Approvals
CE, cUL listed (file E57766), EAC, FM, EN14597 TW approval number TW1222
Transmitter PSU (not 3216i)
Rating: 24V dc, 20mA
Isolation: 264V ac double insulated
Communications
Serial communications option
Protocol: Modbus RTU slave
Modbus RTU Master broadcast (1 parameter)
Isolation: 264V ac, double insulated Transmission standard: EIA232 or EIA485 (2 wire)
Process variable input
Calibration accuracy: <±0.25% of reading ±1LSD (Note 1) Sample rate: 10Hz(100ms)
Isolation: 264V ac double insulation from the PSU and communication
Resolution (μV): <0.5μV with 1.6s filter (mV range)
<0.25mV with 1.6s filter (Volts range) Resolution (effective bits): >17 bits
Linearisation accuracy: < 0.1% of reading
Drift with temperature: <50ppm (typical) <100ppm (worst case) Common mode rejection: 48-62Hz, >-120db
Series mode rejection: 48-62Hz, >-93dB
Input impedance: 100MΩ (200KΩ on volts range C) Cold junction compensation: >30/1 rejection of ambient change External cold junction: Reference of 0°C
Cold junction accuracy: <±1°C at 25°C ambient Linear(process) input range: –10 to 80mV, 0 to 10V requires 100KΩ/
806Ω external divider module (not 32h8i)
Thermocouple types: K, J, N, R, S, B, L, T, C, custom download (Note 2)
Resistance thermometer types: 3-wire Pt100 DIN 43760 Bulb current: 0.2mA
Lead compensation: No error for 22 ohms in all leads
Input filter: Off to 100s
Zero offset: User adjustable over full range
User calibration: 2-point gain & offset
Strain gauge input (32h8i)
Input type: 350Ω Bridge
Connection: 4 or 6 wire (6 uses internal shunt)
Calibration accuracy: +0.1% of full scale
Sample time: 10Hz (100ms)
Isolation: 264V ac double isolation from the PSU and communications
Excitation: 10Vdc +7%
Sensitivity: 1.4 to 4mV/V
Input span: –27% to +127% of full scale (approx.
–10mV to +5mV):
Zero balance: + 25% of full scale
Tare: + 25% of full scale
Resolution (mV): 0.3mV/V(typical) with 1.6s filter Resolution (effective bits): 14.3 bits
Drift with temperature: <100ppm/°C of full scale Common mode rejection: 48-62Hz, >-120db
Series mode rejection: 48-62Hz, >-60db
Input filter: Off to 100s
AA relay
Type: Form C (changeover)
Rating: Min 100mA@12V dc, max 2A@264V ac resistive
Functions: Alarms, events
Digital input A/B
Contact closure: Open >600Ω, closed <300Ω
Input current: <13mA
Isolation: None from PV or system
264V ac double insulated from PSU and communications
Functions: Includes alarm acknowledge, keylock, alarm inhibit, freeze display, tare, auto zero, peak reset
Logic I/O module (3216i only)
Output
Rating: ON 12Vcdc@<44mA, OFF <300mV@100μA
Isolation: None from PV or system
264V ac double insulated from PSU and communications
Functions: Alarms, events
Digital input
Contact closure: Open >500Ω, closed <150Ω
Isolation: None from PV or system
264V ac double insulated from PSU and communications
Functions: Includes alarm acknowledge, keylock, alarm inhibit, freeze display, tare, auto zero, peak reset
Relay output channels
Type 3216i: Form A (normally open) 32h8i, 3204i: Form C (changeover)
Rating: Min 100mA@12V dc, max 2A@264V ac resistive
Functions: Alarms, events
Analogue output
OP1, OP2 (3216i only)
Rating: 0-20mA into <500Ω
Accuracy: ± (<0.5% of Reading + <100μA)
Resolution: 11.5 bits
Isolation: None from PV or system
264V ac double insulated from PSU and communications
Functions: Retransmission
OP 3 (not on 3216i)
Isolation: 264V ac double insulated
Functions: Retransmission
Current Output
Rating: 0-20mA into <500Ω
Accuracy: ±(<0.25% of Reading + <50μA)
Resolution: 13.6 bits
Voltage Output (not on 3204i)
Rating: 0-10V into >500Ω
Accuracy: ±(<0.25% of Reading +<25mV)
Resolution: 13.6 bits
Software features
Alarms
Number: 4
Type: Absolute high & low, Rate of change (rising or falling)
Latching: Auto or manual latching, non-latching, event only
Output assignment: Up to four conditions can be assigned to
one output
Other status outputs
Functions: Including sensor break, power fail, new alarm, pre-alarm
Output assignment: Up to four conditions can be assigned to
one output
Custom messages
Number: 15 scrolling text messages
No of characters: 127 characters per message max
Languages: English, German, French, Spanish, Italian
Selection: Active on any parameter status using conditional command
Recipes
Number: 5 recipes with 19 parameters
Selection: HMI interface, communications or digital IO
Transducer calibration
Calibration types: Shunt, load cell, comparison
Other features: Auto-zero, tare
Other features
Display colour (32h8i): Upper display selectable green or red or
change on alarm
Scrolling text: Parameter help, custom messages
Display filter: Off to zero last 2 digits
Peak monitor: Stores high and low values
FM/EN14597 TW
Alarm 1 configuration: Absolute hi or lo, de-energised in alarm
Latching output on Form C (AA) Relay All alarms active on sensor break and power fail
Alarm setpoint: Adjustment protection via password Configuration security: FM/EN14597 TW option prevents
reconfiguration of alarm config
Eurotherm 3216I/AL/VH/RRX/R/4XL/G/ENG/ENG/XX/XXXX/XXXXXX/XXXXXX////// Temperature Indicator